{"catalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","kind":"record","record":{"attributes":{"category":"physical","domain":"Physical & Environmental Security","type":"preventive"},"canonicalUrl":"https://controlsmap.com/?v=1&node=uc%3AUC-PHYS-06","description":"Protect power equipment and power and telecommunications cabling from interception, interference, and damage, using measures such as protected conduits, separation of power and communications lines, and controlled access to patch panels, wiring closets, and transmission infrastructure. Periodically inspect cabling and access points for tampering or unauthorized devices.","details":{"control_category":"physical","control_type":"preventive","domain":"Physical & Environmental Security","guidance":[],"members":[{"control_id":"PE-4","coverage":"full","framework":"nist-800-53","relationship":"superset_of"},{"control_id":"PE-9","coverage":"full","framework":"nist-800-53","relationship":"superset_of"},{"control_id":"A.7.12","coverage":"full","framework":"iso-27001","relationship":"superset_of"}],"statement":"Protect power equipment and power and telecommunications cabling from interception, interference, and damage, using measures such as protected conduits, separation of power and communications lines, and controlled access to patch panels, wiring closets, and transmission infrastructure. Periodically inspect cabling and access points for tampering or unauthorized devices.","title":"Protect power and communications cabling from damage and taps","unified_id":"UC-PHYS-06"},"id":"uc:UC-PHYS-06","mapUrl":"https://controlsmap.com/?v=1&node=uc%3AUC-PHYS-06","sourceIds":["iso-27001","nist-800-53"],"sourceUrl":null,"title":"UC-PHYS-06 — Protect power and communications cabling from damage and taps","type":"unified"},"relationships":[{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:12b717e1c62fb60a27cf9b07ac12fb03f5084c126549b277eb567e36d267f85e","properties":{"control_id":"PE-4","coverage":"full","delta":null,"framework":"nist-800-53","provenance":{"defaultConfidence":"medium","defaultStatus":"active","direction":"canonical_to_source","mapper":"coworkcanvas-compliance-graph","note":"Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.","reviewDate":"2026-09-07"},"relationship":"superset_of","source_version":"Rev. 5"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/ctrl-nist-800-53-pe-4-fcf1523c.json","targetId":"ctrl:nist-800-53:PE-4","type":"maps_to"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:190977c444152b5b0617e888e756f088cb962578679338e772b31d447349ec30","properties":{},"sourceDetailPath":"/data/v1/records/wf-c36-f731c649.json","sourceId":"wf:C36","targetDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","targetId":"uc:UC-PHYS-06","type":"operates"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:31b6d4ceb31573682d32aab382647207340a0be4554ed590a7548681e58b0dbb","properties":{"rationale":"Protected conduits and inspection for tampering/rogue devices defend power and comms infrastructure against physical sabotage.","strength":"related"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/risk-phys-cyber-physical-facility-attack-e372d06e.json","targetId":"risk:phys-cyber-physical-facility-attack","type":"mitigates"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:56a78f724c7433fa94466e54123e2bf28fa4f3acf3cd928cc81a5458f0d38243","properties":{},"sourceDetailPath":"/data/v1/records/wf-c9-75fb1752.json","sourceId":"wf:C9","targetDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","targetId":"uc:UC-PHYS-06","type":"tests"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:6644e588b43c8580cee61fb0a1e309e2eb5fbd68ca42e6986775487ba1419207","properties":{"control_id":"PE-9","coverage":"full","delta":null,"framework":"nist-800-53","provenance":{"defaultConfidence":"medium","defaultStatus":"active","direction":"canonical_to_source","mapper":"coworkcanvas-compliance-graph","note":"Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.","reviewDate":"2026-09-07"},"relationship":"superset_of","source_version":"Rev. 5"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/ctrl-nist-800-53-pe-9-25fa60ff.json","targetId":"ctrl:nist-800-53:PE-9","type":"maps_to"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:717bd5d53b9127ada6428fe8fdba0cb474e4f17e248a6a706112028a8119e6c3","properties":{"control_id":"A.7.12","coverage":"full","delta":null,"framework":"iso-27001","provenance":{"defaultConfidence":"medium","defaultStatus":"active","direction":"canonical_to_source","mapper":"coworkcanvas-compliance-graph","note":"Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.","reviewDate":"2026-09-07"},"relationship":"superset_of","source_version":"2022"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/ctrl-iso-27001-a-7-12-f450aaa2.json","targetId":"ctrl:iso-27001:A.7.12","type":"maps_to"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:cd721472ad16564ab5ec24037a336128b104e278a0aebd781071f1b30b747f26","properties":{},"sourceDetailPath":"/data/v1/records/wf-d06-c9616fb8.json","sourceId":"wf:D06","targetDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","targetId":"uc:UC-PHYS-06","type":"tests"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:d4e86f7d21e1065fbaa26e07d9425eebb9cc86b01e6388268f6d51b7308e52a8","properties":{"rationale":"Protected conduits, line separation, and tamper inspection address the cabling-damage clause, but the operative defense against this risk's fire/flood core is suppression and drainage (UC-PHYS-03).","strength":"related"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/risk-phys-fire-water-suppression-gap-ac966b92.json","targetId":"risk:phys-fire-water-suppression-gap","type":"mitigates"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:fee8fabdc6c1507dafb986fe82c35784167adc82c4d7f8d431a11b3b29ad02db","properties":{},"sourceDetailPath":"/data/v1/records/wf-c7-acbef2ee.json","sourceId":"wf:C7","targetDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","targetId":"uc:UC-PHYS-06","type":"oversees"},{"expectedCatalogRevision":"24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028","id":"rel:feea54d15334313f75a45b3a3c47ccc60c161d8b8ce000d090d220aca7ab013b","properties":{"rationale":"Protecting power/telecom cabling from damage and disconnection prevents cable-cut power and carrier outages.","strength":"related"},"sourceDetailPath":"/data/v1/records/uc-uc-phys-06-1be360d8.json","sourceId":"uc:UC-PHYS-06","targetDetailPath":"/data/v1/records/risk-tech-loss-essential-services-b7feae05.json","targetId":"risk:tech-loss-essential-services","type":"mitigates"}],"schemaVersion":1}