unified
UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities
Protect supporting utilities such as power, HVAC, and telecommunications from failure and disruption, with inspection and maintenance on a defined schedule. Provide uninterruptible power and generator capacity sized to enable orderly shutdown or continued operation of critical systems, and automatic emergency lighting covering evacuation routes. Provide accessible, protected emergency shutoff capability to cut power to systems safely in an emergency.
Record JSON · Open in map · Data retrieval guide
Catalog revision: 24028ffcfc2b295fa1b08ee6caa84b765f0731b321496bf4f548c49ad2177028. A connection does not establish full coverage.
Attributes
- domain
- Physical & Environmental Security
- type
- corrective
- category
- physical
Details
- unified_id
- UC-PHYS-05
- title
- Provide emergency power, lighting, and resilient utilities
- statement
- Protect supporting utilities such as power, HVAC, and telecommunications from failure and disruption, with inspection and maintenance on a defined schedule. Provide uninterruptible power and generator capacity sized to enable orderly shutdown or continued operation of critical systems, and automatic emergency lighting covering evacuation routes. Provide accessible, protected emergency shutoff capability to cut power to systems safely in an emergency.
- domain
- Physical & Environmental Security
- control_type
- corrective
- control_category
- physical
- members
- framework
- nist-800-53
- control_id
- PE-10
- coverage
- full
- relationship
- superset_of
- framework
- nist-800-53
- control_id
- PE-11
- coverage
- full
- relationship
- superset_of
- framework
- nist-800-53
- control_id
- PE-12
- coverage
- full
- relationship
- superset_of
- framework
- iso-27001
- control_id
- A.7.11
- coverage
- full
- relationship
- superset_of
- guidance
Source
No record-specific source URL is provided.
Connections
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities mitigates Physical and cyber-physical attacks on facilities and infrastructure
- strength
- related
- rationale
- Backup power and generators sustain operation when an adversary cuts power/utilities, mitigating attack impact.
- ISO 27001 Stage 2 Annex A Controls Audit tests UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities maps_to PE-10 — Emergency Shutoff
- framework
- nist-800-53
- control_id
- PE-10
- coverage
- full
- relationship
- superset_of
- delta
- Not provided
- source_version
- Rev. 5
- provenance
- mapper
- coworkcanvas-compliance-graph
- reviewDate
- 2026-09-07
- direction
- canonical_to_source
- defaultConfidence
- medium
- defaultStatus
- active
- note
- Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities mitigates Loss of essential services (power, HVAC, telecoms)
- strength
- primary
- rationale
- UPS, generators, and protected/maintained utilities are the direct defense against loss of power, HVAC, and telecom.
- Environmental & Utility Systems Maintenance operates UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities mitigates Workplace health, safety and well-being failures
- strength
- related
- rationale
- Automatic emergency lighting on evacuation routes and safe emergency power shutoff protect personnel during emergencies.
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities maps_to PE-11 — Emergency Power
- framework
- nist-800-53
- control_id
- PE-11
- coverage
- full
- relationship
- superset_of
- delta
- Not provided
- source_version
- Rev. 5
- provenance
- mapper
- coworkcanvas-compliance-graph
- reviewDate
- 2026-09-07
- direction
- canonical_to_source
- defaultConfidence
- medium
- defaultStatus
- active
- note
- Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities mitigates Physical damage to assets from disaster, terrorism or vandalism
- strength
- related
- rationale
- Emergency power and evacuation lighting enable orderly shutdown and safe egress during disasters, reducing harm and loss.
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities maps_to PE-12 — Emergency Lighting
- framework
- nist-800-53
- control_id
- PE-12
- coverage
- full
- relationship
- superset_of
- delta
- Not provided
- source_version
- Rev. 5
- provenance
- mapper
- coworkcanvas-compliance-graph
- reviewDate
- 2026-09-07
- direction
- canonical_to_source
- defaultConfidence
- medium
- defaultStatus
- active
- note
- Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.
- ISO 27001 SoA Review & Controls Assessment oversees UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities mitigates Environmental degradation of equipment (dust, humidity, temperature, EMI)
- strength
- related
- rationale
- Power conditioning prevents voltage-variation damage and protected HVAC prevents thermal degradation of equipment.
- Security Control Assessment & POA&M Remediation tests UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities
- UC-PHYS-05 — Provide emergency power, lighting, and resilient utilities maps_to A.7.11 — Supporting utilities
- framework
- iso-27001
- control_id
- A.7.11
- coverage
- full
- relationship
- superset_of
- delta
- Not provided
- source_version
- 2022
- provenance
- mapper
- coworkcanvas-compliance-graph
- reviewDate
- 2026-09-07
- direction
- canonical_to_source
- defaultConfidence
- medium
- defaultStatus
- active
- note
- Each member is a documented relationship claim from the canonical unified control to a source control or guidance proposition. relationship: equal|superset_of (full) / intersects_with|subset_of (partial) / informs (guidance). confidence 'medium' = single-mapper, documented, not yet externally corroborated. source_version is the member framework's edition from the standard version register.